Trakya Cam Sanayii A.Þ.
Home Products References CE Contact Türkçe
www.trakyacam.com.tr
   
Brands
Functions
Applications
Types
Types
 
TRC ECOSOL
Heat and Solar Control Glass
 
Processing
 
 
> Heat and Solar Control Coating on Clear Float Glass
 
  • Particular care should be taken for transporting, storing, cutting and washing of heat and solar control coating on clear float glass TRC Ecosol.

  • TRC Ecosol is affected by acid. Since human perspiration is acidic, care must be taken that the coating is not damaged by fingerprints. Wearing clean and waterproof gloves is therefore absolutely essential when manipulating coated glass. Dirty and oily gloves should be changed immediately. They can be used again after truly washing and drying.

  • During the cutting process of coated glass, care should be taken that the uncoated side of the glass is placed downwards to the cutting table. It is always the coated side that is scored. Suction cups should be applied to the uncoated surface when placing the glass to the cutting table. Manual cutting is not recommended for soft TRC Ecosol. For machine cutting, highly volatile cutting oil must be used.

  • Before insulating glass unit production heat and solar coating must be removed 10 mm from the edges of the TRC Ecosol

  • TRC Ecosol should be washed with soft bristle brushes and demineralized water with a conductance not exceeding 30 µs/cm should be used.

  • Cut size TRC Ecosol panes must not be left out unpacked. All processes from cutting through to insulating glass unit assembly must be completed in the same day.

  • The heat and solar control coating should be placed on the second surface of the insulating glass unit.
  • Provided the below instructions are followed, the storage time for a sealed stack of TRC Ecosol is 6 months.

    • TRC Ecosol packs must not be uncovered until the temperature of the pack and that of each individual glass pane has reached to equilibrium with the temperature of the processing hall. (Opening stacks or packs before achieving the production hall temperatures, may entail condensation of humidity in between the individual panes with adverse effects on the coating.)

    • Condensation may be observed on the outer surface of the first and last glass panes. While unpacking, there is a possibility of water droplets to get between the glass panes In order to avoid this situation corresponding glass panes should be dried properly.

    • Also the packaging material of glass packs and stacks should not be removed until the cutting process.

    • The temperature of the plant area should not fall below 15oC. Storage in the vicinity of doors must be avoided.

    • The plant, production hall and transportation areas should be free of aggressive fumes. (Particular care should be taken that the hydrochloric acid etc. substances should not be stored at the same area.)

    • After the surrounding tape of the TRC Ecosol has been removed, any remains of dehumidifying agent must be removed from the upper edge of the stack or pack. Any dehumidifying agent remaining on the upper edge of the glass will produce scratches when it enters into the space between the panes on handling of the individual sheets. Residue on the uncoated side by the surrounding tape can be cleaned by mild agents and ethyl alcohol.

    • Remaining pieces or lites of the TRC Ecosol should be re-sealed using the same packing materials, renewing the dehumidifying agent. Before packaging operation, the color of the randomly chosen dehumidifying agent should be checked. In case the color of the dehumidifying agent is pink, then it should be changed.
 
 
> TRC Ecosol can be produced by applying heat and solar coating on different thicknesses of cut size toughened     or heat strengthened clear/body tinted float glass on project basis.
 
 
< Back
 
 
 
Legal Information Site Map